Magnum-venus-plastech UltraMAX HVLS-1000 Series User Manual Page 31

  • Download
  • Add to my manuals
  • Print
  • Page
    / 40
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 30
HVLS-1000 Series Fluid Section Manual
Rev. 05/2012 Page | 31
Remove and Disassemble Filter:
1. Unscrew the filter cap (FF-5002) from the filter body (FF-5001).
NOTE: The components of the resin accumulator and filter should not be over tightened.
NOTE: Typically the High Volume units do not have screens in the filter body.
2. Inspect the interior of the filter body and clean with solvent.
3. Check the O-Ring (O-V-022) on the filter cap for wear or damage. Replace if necessary.
NOTE: If resin is leaking down the side of the filter cap, the O-Ring (O-V-022) is worn and
should be replaced.
Assemble and Install Filter Body:
1. Lubricate the threads of the filter cap (FF-5002) and o-ring (O-V-022) with red grease
(6706-2-1).
2. Screw the filter cap into the filter body (FF-5001).
Remove Accumulator Bottle:
DANGER: Before disassembling accumulator, relieve fluid pressure and air pressure. If
material is plugging the system, some parts of the system may still contain fluids under
high pressure, even after you have followed normal procedures to relieve the pressure.
1. Unscrew the surge chamber from the nipple
2. Inspect the interior of the accumulator bottle. Clean with solvent and blow dry with air if
needed.
Install Accumulator Bottle:
1. Screw the nipple and surge chamber into the top of the filter body (FF-5001).
2. Check for leaks