HVLS-1000 Series Fluid Section Manual
Rev. 05/2012 Page | 24
Disassembly of Fluid Section:
NOTE: Flushing the pump fluid section with solvent will make it easier to clean and
rebuild.
CAUTION: There are two (2) hard chrome balls in the Fluid Section assembly. If a ball
drops to the floor, it will be damaged. (Even if it appears undamaged, it will contain
dents and scratches that will create problems.) Damaged balls must be replaced or the
pump will not work properly.
NOTE: When disassembling the Fluid Section, replace any O-Rings that you expose.
Maintenance:
1. For a complete maintenance schedule, please refer to Chapter 3: Maintenance.
Troubleshooting:
1. For a complete troubleshooting schedule, please refer to Chapter 7: Troubleshooting
Chart.
Parts Drawings:
1. To perform service and repair on the Fluid Section, please follow the procedures below.
Please refer to a current parts drawing for the Fluid Section you are working on for part
numbers.
Turn Off Pressure:
1. Be sure all fluid pressure and air pressure is relieved from the system before performing
any work.
DANGER: To avoid serious injury or equipment damage, do not proceed unless the
system has been completely depressurized.
Remove Catalyst Pump:
1. Be sure the catalyst pump has been removed from the catalyst drive.
Note: some of the part numbers below will be different depending on which fluid section
you are working on – refer to a current parts drawing for the assembly you are working
on.