Resin Heaters
Important Note
It is essential that resin heaters are not left turned on with stationary resin in the system.
Uncatalysed resin will eventually cure at elevated temperatures and block the heater
channels..
Whilst the resin heater is on, the machine MUST be either recirculating or injecting.
At the end of a shift, turn off the resin heater and continue to recirculate the machine until
the resin has cooled to room temperature. It is then safe to turn off the machine.