Magnum-venus-plastech Megaject MKIV Revision 1_6 User Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 41
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
Megaject MK V Issue 1_6 Page 4 of 41
Injection Head
1. Resin recirculation valves. Swap the resin streams between the injection and
the recirculation position. (90° movement)
2. Catalyst recirculation valve not shown (Polyester option only). Swaps
the catalyst stream between the injection and recirculation positions. (180°
movement)
Note: Recirculation valves must be turned to their full extent for correct
operation i.e. 90° for resin and 180° for catalyst
3. Thumb Start Switch. Used to start machine for injection. Will only operate
when recirculation valves are in the injection position.
4. Autosprue Connector (for use with Autosprue option only)
5. Resin and Catalyst Interlock Switches. Check that both resin and catalyst
recirculation valves are in the inject position.
1
1
3
4
5
Page view 3
1 2 3 4 5 6 7 8 9 ... 40 41

Comments to this Manuals

No comments