Magnum-venus-plastech HIS SUPERCHARGED User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
SUPERCHARGED H.I.S.™
1. Check all fittings for proper connection.
2. Fill resin pump power head oiler to designated mark on oiler using light
weight oil provided with the unit or available from MVP when supply is
depleted. (See Fig. 2A)
3. Fill resin pump cavity (center section) approximately 1/3 full using the oil
provided, or a standard 30 weight motor oil. (See Fig. 2B)
4. Turn all regulators counter-clockwise so gauges will read zero when air
is connected to system. (See Fig. 2C)
5. Pull top quick pin from catalyst pump slave arm. (See Fig. 2D)
Start-up procedure
The following steps should be followed when the unit is
new, has been recently repaired or has no material in the
system.
NOTE
Fig. 2A Fig. 2B
1
Chapter
22
22
2
Page view 4
1 2 3 4 5 6 7 8 9 10 ... 27 28

Comments to this Manuals

No comments